| General | |
| DVM -- PFC_CCM_sync_DLL.sxsch |
| dvm_advanced.testplan |
| POP on AC-DC CCM PFC.testplan |
| 2022-03-22 06:18 |
| DVM_REPORTS\2022-03-22-06_18 |
| dvm_advanced.log |
| 4 of 4 (All Pass) |
| 1h 19m 36s |
|
| Design Specifications | |
| Critical Conduction Mode PFC |
| with prototype PFC POP trigger |
| 120.2082 VRMS Nominal (100 VRMS to 155.563 VRMS) |
| 220 VRMS Nominal (170 VRMS to 265 VRMS) |
| 400 V (±5%) @ 250m A |
| 50Hz |
| 60Hz |
| 400kHz |
|
| Excel-compatible Results | |
| dvm_advanced_table_scalars.txt |
| dvm_advanced_table_specs.txt |
| dvm_advanced_table_statistics.txt |
| dvm_advanced_table_statspecs.txt |
|
| Test 1 of 4 | |
| LL_Nominal|F_Low|Disabled|100% Load|FindACSteadyState |
| simplis |
| LL_Nominal\F_Low\Disabled\100% Load\FindACSteadyState\report.txt.html |
| PASS |
| 22m 11s |
|
| Test 2 of 4 | |
| LL_Nominal|F_Low|Disabled|100% Load|BodePlot |
| simplis |
| LL_Nominal\F_Low\Disabled\100% Load\BodePlot\report.txt.html |
| PASS |
| 21m 36s |
|
| Test 3 of 4 | |
| LL_Nominal|F_Low|Disabled|80% Load|FindACSteadyState |
| simplis |
| LL_Nominal\F_Low\Disabled\80% Load\FindACSteadyState\report.txt.html |
| PASS |
| 26m 0s |
|
| Test 4 of 4 | |
| LL_Nominal|F_Low|Disabled|80% Load|BodePlot |
| simplis |
| LL_Nominal\F_Low\Disabled\80% Load\BodePlot\report.txt.html |
| PASS |
| 9m 43s |